- Process error if typeplate is no longer recognized (work can continue as normal)
- Process error when Visu is started and no screwdriver unit is recognized
- Warning if Visu is started and the screwdriver unit does not have a nameplate
- Homing offset is fixed at -3.00 mm
- Hold-down device Min. adjustment value is permanently defined as 1.00
- Hold-down maximum adjustment value is permanently defined as 1.50
- Integration of new feeding system magazine
- Optimization of the calibration process
- Extension of the error messages
- Bugfixes
• Force reduction after feed drive force error during base position drive
• Optimization of the function Running in
• ScrollView for ErrorMessagePage for fitting into window
• Revision of the fastener tracking in the system
• Optimization of the display of step number in graph
• Revision of the feeding while activation or deactivation of higher level controler
• Optimization of the engagement process
• Revision of the setpoint of downholder position
• Extension of error messages for downholder: Problems by setting position to zero
- messages for predictive maintenance 
- detailed error messages and proposed solutions
- optimized feeding 
Optimisation:
- Revision of the saving pocedure of the fieldbus settings (Ticket: 44146)
- Revision and extension of the manual (Ticket: 44155)
- Optimisation of the screwdriving process (Ticket: 44172/44127)
- Optimisation of return stroke
- Optimisation of the process step finding
- Optimisation of the acceleration ramp
- New warning: No. 7 "Process terminated: Fastener not assembled completely."
- Languages revised (Korean added) (Ticket: 44122)
- Optimisation of the parameter template (saving of values) (Ticket: 44154)
- Optimisation of external service functions (also available if an error is pending) (Ticket: 44186)
- Optimisation of request handling for higher level controller (Ticket: 44151/ 44128)
- Request cleaning if error 1803 is pending
- Requests are generated one after the other in a meaningful sequence and no longer simultaneously
- Revision of the storage and display of the final value data (Ticket: 44150)
- Optimisation of usability (acknowledging errors, even during an active function or screwdriving process) (Ticket: 44164/44161/44170)
- Extension: The reference position is saved on the type plate
- Reset of the downholder position revised ( Position will be set to 0 only during the referencing)
- Optimisation of the feeding (screw detection only active during feeding) (Ticket: 44163)
- Revision of MQTT (Ticket: 44145)
- MQTT curves are not passed on
- Authorisations for OPC UA and MQTT adapted
- MQTT message buffer limited
- Revision of the data set selection (Ticket: 44123)
- Data records are not deleted after an emergency stop
- Revision of the data set selection (selection by data set name)
- Only an error message when selecting an incorrect data record
- Optimisation of the backup function (Task 26459)
- Troubleshooting Save system image
- "Restarter stopped working" information corrected
- Restarter window is no longer displayed (Task 25892)
- Revision of the tool changing process
- Optimisation of feeding process (automatic feeding of the fastener deactivated)
- Translations revised
- Application of several repeaters possible
- Extension of the error messages
- New error messages
- Cover feeding system closed
- Booster available Yes/No
- Converter failure
- Error of downholder, if bus module has a malfunction
- No feeding system connected
- Head undocked
- Optimisation of voltage monitoring e.g. docking 1911 2011
- Product maintenance
•	Two-level piercing
•	Option for connection of a new feeder: vibratory spiral feeder
•	Adjustment of maximum robot force in data sets 
•	Optimisation of the interface for connection of a higher-level controller
•	Extensions to the text
•	Detailed diagnosis and support 
- Support of the message log MQTT
- Support of the DEPRAG cockpit
- Reduced Cycle time (100-200ms)
- Confirmmessage "Close HMI"
- optimized process control
- Typeplate: set default to minimum
- Optimized coding and dataset number
- Support for upgraded rotary device 
- Integration of Windows 10
- Optimized visualisation process steps
- Support for DPU210
- Update must be activated first
- Userinterface fieldbus extended
Servicepack
- Extended configuration options for Ethernet IP
- Optimisation of the processing sequences and adjustments to the motion commands 
- Improved diagnosis options due to detailed instructions
- Extended plausibility tests in process parameterisation 
- Message 539 has been removed
- Improved usability in the visualisation 
- Optimised feed supervision 
- Improved regulator control and reduction of processing time
- Automatic calibration of the ADAPTIVE DFS
- New process type: Flow Push Plus
- Improved user handling and optimised charging times
- Improved graphic recording and diagnosis options 
- System messages contain detailed information with descriptions 
- Upgraded screwdriving program plausibility checks
- Optimised head exchange